Surface preparation
The surface must be clean and dry, free from dust or loose rust. Manual or mechanical brushing will be carried out to achieve a surface condition corresponding to degree ST3 of ISO 8501-1.
Implementation temperature
The temperature of the surface to be coated must be at least 5° above the dew point, with a minimum of 10°C.
Application of the tape
The tape is applied in a spiral, under tension to ensure contact between the adhesive and the entire surface to be coated, with a minimum overlap of 50%*.
After coating, smooth the strip well to close the turns and form a continuous coating.
*To achieve class A of EN 12068, coat with 66% coverage or apply mechanical protection
TEDOTEC SA 337 route de l'Etat - 1380 LASNE - Belgium info@tedotec.com 32 (0)2 652 46 08 32 (0) 475 474 202 33 (0)6 15 15 46 32